Avelec
for use with fuel or oil Basic Sensor
Telemetry Adapter Module.

General:
Operating temperatures up to 120°C.
Input from remote Basic Sensor.
Output Suitable for connection to in-vehicle Logger inputs and
Telemetry inputs.
Simultaneous connection to panel readout. (optional)
User selectable damping to eliminate surging.
High speed Low level warning - for fast response to sudden fluid
loss.
Telemetry System compatible output - 1 to 5 volt DC or 0.5 to
4.5 Volt DC.
Instant pushbutton calibration
- no voltmeter required.
Fully encapsulated electronics.
Back to Top
Electrical:
Power consumption: 10.5 to 20 VDC, 50mA typ. (see
notes.)
Operating temperature range: -20 to +120°C.
Output: 1 to 5 volts or 0.5 to 4.5 volts linear with
depth in 56 steps. Optional output to panel instrument available.
Response: Two levels of damping user selected with
one connector pin - full to empty in approx 4 secs or approx
100 secs. (Typical values - dependent on sensor length and fluid properties)
Low level warning: 5 volt fast response output at
user settable level.
Electrical connectors: Deutsch AS Autosport &
optional BNC for simultaneous panel readout.
Notes: a) Use only power supplies with voltage excursions
inside specified limits.
b) Supply current varies with supply voltage.
Back to Top
Mechanical:
Housing Dimensions: W - 100mm, D - 50mm, H - 25mm.
Material: Diecast Aluminium.
Back to Top
Specifications:
General
Electrical
Mechanical